HK-1001B Fully Automatic Cleveland Open-Cup Apparatus conforms to ASTM D92 Test Method for Flash and Fire Points by Cleveland Open Cup Tester.

It uses the Cleveland Open Cup method to test the flash point&fire point of lubricating oil and fuscous petroleum products. (Excluding fuel oil and petroleum products with open flash point lower than 79℃)

  HK-1001B Fully Automatic Cleveland Open Cup Apparatus

HK-1002B Automatic Cleveland Open Cup and Pensky-Martens closed cup flash point tester conforms to the ASTM D92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester, is used for open and closed cup flash point of petroleum products.

  HK-1002B Automatic Cleveland Open Cup and Pensky-Martens Closed Cup Flash Point Tester


HK-1002C Automatic Pensky-Martens closed-cup flash point apparatus conforms to the ASTM D93 Standard test methods for flash point by Pensky-Martens Closed Cup Tester.

This tester covers the determination of the flash point of petroleum products in the temperature range from 40 to 360°C by an automated Pensky-Martens closed-cup apparatus, and the determination of the flash point of biodiesel in the temperature range of 60 to 190°C.

HK-1002c Automatic Pensky Martens Closed-Cup Flash Point Apparatus


K-21929A Automatic Tag closed cup flash point apparatus conforms to the ASTM D56 Standard Test Method for Flash Point by Tag Closed Cup Tester.

It is used For flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash point below 200°F (93°C) except cut-back asphalts, those liquids which tend to form a surface film under test conditions and materials which contain suspended solids.

We use gas supply for the apparatus, gas circuit adopts stainless steel pipe, anti-aging, constant using.

The instrument is highly automated with simple operation and accurate result. The instrument is equipped with two Danfoss compressors as a cooling system, test lowest flash point temperature can reach minus 50 degrees.

HK-21929A Automatic Tag Closed Cup Flash Point Apparatus


HK-261 Manual Pensky-Martens Closed-cup Flash Point Apparatus conforms to the ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester.

It is used to test for those liquids which have a kinematic viscosity of 5.8 mm 2/s (cSt) or more at 37.8°C or 9.5 mm 2/s (cSt) or more at 25°C (77°F), or that contain suspended solids, or have a tendency to form a surface film while under test. Other classification flashpoints have been established by these departments for liquids using these test methods.

HK-261 Manual Pensky-Martens Closed-Cup Flash Point Apparatus 


HK-261A Semi-automatic Pensky-Martens Closed-cup Flash Point Apparatus conforms to the ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester.

It is used to test for those liquids which have a kinematic viscosity of 5.8 mm 2/s (cSt) or more at 37.8°C or 9.5 mm 2/s (cSt) or more at 25°C (77°F), or that contain suspended solids, or have a tendency to form a surface film while under test. Other classification flash points have been established by these departments for liquids using these test methods.

HK-261A Semi automatic Pensky Martens Closed-cup Flash Point Apparatus


HK-261B Automatic Pensky-Martens Closed Cup Flash Point Tester conforms toASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to test for those liquids which have a kinematic viscosity of 5.8mm 2/s.

It is used to test for those liquids which have a kinematic viscosity of 5.8mm 2/s (cSt) or more at 37.8℃ or 9.5mm 2/s (cSt) or more at 25℃ (77℉), or that contain suspended solids, or have a tendency to form a surface film while under test. Other classification flash points have been established by these departments for liquids using these test methods.

HK-261B Automatic Pensky-Martens Closed Cup Flash Point Tester

HK-267 Open-Cup Flash & Fire Point Apparatus conforms to the GB/T 267 standard. Use crucible as ​sample oil holder, the apparatus used to test the flash point & fire point of lubricating oil and fuscous petroleum products.

HK-267 Open-Cup Flash & Fire Point Apparatus

HK-3536 Manual Cleceland Open Cup Apparatus conforms to the ASTM D92 Test Standard method for Flash and Fire Points by Cleveland open Cup Tester.

It uses Cleveland open-cup method to test the flash point & fire point of lubricating oil and fuscous petroleum products (excluding fuel oil and petroleum products with open flash point lower than 79°C ).

HK-3536 Manual Cleveland Open Cup Apparatus


HK-3536A  Semi-automatic Cleveland Open-Cup Apparatus is suitable to the standards of ASTM D92Test Method for Flash and Fire Points by Cleveland Open Cup Tester.

It uses Cleveland Open Cup method to test the flash point &fire point of lubricating oil and fuscous petroleum products(excluding fuel oil and petroleum products with open flash point lower than 79°C.